Wet chemical fire extinguisher - Frost resistant
FN3 ECO
Economy Line with all-metal valve assembly, pressure gauge and test valve
DÖKA stored-pressure wet chemical fire extinguishers feature an extinguishing agent container made of high-quality sheet steel. The high-grade polyester resin coating is durable and weather-resistant, protecting the container against corrosion. The metal valve assembly, featuring a forged brass body, comes equipped as standard with a pressure gauge and a separate test valve.
The extinguishing agent: a fluorine-free agent for fire classes A and F, specifically for grease fires
This specialized extinguishing agent—which is also suitable for fire class A (combustible solids)—forms a thick barrier layer over grease fires, cutting off the oxygen supply and smothering the flames. At the same time, the agent ensures rapid cooling, effectively preventing re-ignition. It is frost-resistant down to -30°C, making the DÖKA FN3 ECO suitable for use in outdoor areas, such as food trucks.
Versions
Capacity: 3 ltr. Aqueous solution
Rating: 8A / 40F
Dimensions H x W x D ca. mm: 470 x 185 x 135
Weight: ca. kg: 6,1
Throwrange ca. m: 4-6
Discharge time ca. Sek.: 18
Operating temp. °C: -30 bis +60
Approval MED 2014/90/EU: Yes
Packaging: Single packaging, 64 Units per palett
Features
GPSR Information
Product data sheet: see Downloads
Operating instructions and declaration of conformity: see Downloads
Material safety data sheet for extinguishing agents: see Downloads
Safety instructions
- Operate the fire extinguisher in accordance with the pictograms and instructions printed on the fire extinguisher‘s operating plate, taking into account the additional information and instructions.
- The minimum and maximum temperature limits specified on the operating plate must be observed. Do not expose to cold or heat radiation if this causes the minimum or maximum temperature limit to be exceeded or fallen short of. Store fire extinguishers in frost-free areas. Protect from UV radiation.
- The use of CO2 and powder fire extinguishers can lead to electrostatic charging.
- CO2 fire extinguishers may only be used when people are present in rooms if there is a free floor area of >5.5 m² per kg of CO2. There is a risk of suffocation. • Do not direct the extinguishing agent jet at people from a short distance, especially not at the head. There is a risk of suffocation and CO2 fire extinguishers can cause cold burns.
- Fire extinguishers can be pressurised. Do not expose to force, do not open by force.
- If pressurised parts are damaged or corroded, the fire extinguisher must be depressurised and repaired immediately by a competent person.
- Only use fire extinguishers for their intended purpose. Do not make any structural modifications. • Fire extinguishers must be installed or set up in such a way that they are easily visible and accessible and protected against falling over or falling down and damage.
- Never carry fire extinguishers loose in the vehicle. Transport is only permitted with proper securing and in the original sealed carton or equivalent safety measures. Special brackets are required to carry fire extinguishers on or in vehicles at all times, and these must be fitted professionally. Fire extinguishers must be mounted in such a way that they cannot be damaged by the expected vibrations or movements, or even fall out of the holder. If the fire extinguisher is to be mounted on the outside of the vehicle, it must also be placed in a protective container.
- Keep fire extinguishers clean, do not use aggressive cleaning agents, only clean with a damp cloth.
- Only have fire extinguishers completely emptied and depressurised disposed of by a recognised disposal company.
- For cooking oil and cooking fat fires, only use fire extinguishers specially designed for fire class F!
- Keep away from children
Packaging consisting of*:
| Outer carton, cardboard, PAP 20 | ![]() |
| PE-LD protective film | ![]() |
* Details for standard shipping
- Fire extinguisher
- Wall bracket
- Operating Instructions / Declaration of Conformity
Technische Daten
| Operating system | Permanent pressure |
|---|---|
| Fire class A Rating | 8 |
| Fire class F Rating | 5 |
| Capacity | 3 ltr. |
| Extinguishing agent | Wet chemical AF |
| Fluorine free | Yes |
| Temperature range °C | -30 to +60 |


