Permanent pressure foam fire extinguisher SN-TAF ECO Frost protected

Reference 1256-8120
Choose type

Foam fire extinguishers - Frost resistant
SN6TAF ECO | SN9TAF ECO

Economy Line with all-metal valve assembly, pressure gauge and test valve

DÖKA stored-pressure foam fire extinguishers feature an extinguishing agent container made of high-quality sheet steel. The high-grade polyester resin coating is durable and weather-resistant, protecting the container against corrosion. The metal valve assembly, featuring a forged brass body, comes equipped as standard with a pressure gauge and a separate test valve.

The extinguishing agent: Frost-resistant foam

Foam extinguishing agents are produced by mixing air into a water/foam concentrate blend. When fighting fires involving solid materials (Class A fires), the foam’s excellent extinguishing performance stems primarily from its high wetting capability, combined with the interruption of gas exchange and a cooling effect. The addition of salts allows this foam to be used even in freezing temperatures.

  • Fluorine-free: We use modern, completely fluorine-free foam concentrates.
  • Powerful effect: The foam cools the seat of the fire and blankets the flames. This cuts off the fire's oxygen supply, causing it to extinguish immediately—whether the fire involves solid materials or burning liquids.
  • Frost-resistant: Effective even at low temperatures.

Versions

Capacity: 6 ltr. foam
Rating: 27A / 113B
Dimensions H x W x D ca. mm: 525 x 270 x 170
Weight ca. kg: 10,4
Throw range ca. m: 4-6
Discharge time ca. Sek.: 22
Operating temp. °C: -25 to +60

Packaging: Single packaging, 56 Units per palett

Capacity: 9 kg ltr. foam
Rating: 34A / 183B
Dimensions H x W x D ca. mm: 575 x 270 x 195
Weight ca. kg: 14,2
Throw range ca. m: 4-6
Discharge time ca. Sek.: 43
Operating temp. °C: -25 to +60

Packaging: Single packaging, 30 Units per palett

Features

GPSR Information

DÖKA Feuerlöschgerätebau GmbH
Antonius-Raab-Straße 18
34123 Kassel
Deutschland

Kontakt

Product data sheet: see Downloads
Operating instructions and declaration of conformity: see Downloads
Material safety data sheet for extinguishing agents: see Downloads

Safety instructions

  • Operate the fire extinguisher in accordance with the pictograms and instructions printed on the fire extinguisher‘s operating plate, taking into account the additional information and instructions.
  • The minimum and maximum temperature limits specified on the operating plate must be observed. Do not expose to cold or heat radiation if this causes the minimum or maximum temperature limit to be exceeded or fallen short of. Store fire extinguishers in frost-free areas. Protect from UV radiation.
  • The use of CO2 and powder fire extinguishers can lead to electrostatic charging.
  • CO2 fire extinguishers may only be used when people are present in rooms if there is a free floor area of >5.5 m² per kg of CO2. There is a risk of suffocation. • Do not direct the extinguishing agent jet at people from a short distance, especially not at the head. There is a risk of suffocation and CO2 fire extinguishers can cause cold burns.
  • Fire extinguishers can be pressurised. Do not expose to force, do not open by force.
  • If pressurised parts are damaged or corroded, the fire extinguisher must be depressurised and repaired immediately by a competent person.
  • Only use fire extinguishers for their intended purpose. Do not make any structural modifications. • Fire extinguishers must be installed or set up in such a way that they are easily visible and accessible and protected against falling over or falling down and damage.
  • Never carry fire extinguishers loose in the vehicle. Transport is only permitted with proper securing and in the original sealed carton or equivalent safety measures. Special brackets are required to carry fire extinguishers on or in vehicles at all times, and these must be fitted professionally. Fire extinguishers must be mounted in such a way that they cannot be damaged by the expected vibrations or movements, or even fall out of the holder. If the fire extinguisher is to be mounted on the outside of the vehicle, it must also be placed in a protective container.
  • Keep fire extinguishers clean, do not use aggressive cleaning agents, only clean with a damp cloth.
  • Only have fire extinguishers completely emptied and depressurised disposed of by a recognised disposal company.
  • For cooking oil and cooking fat fires, only use fire extinguishers specially designed for fire class F!
  • Keep away from children

Packaging consisting of*:

Outer carton, cardboard, PAP 20
PE-LD protective film

* Details for standard shipping

  • Fire extinguisher
  • Wall bracket
  • Operating Instructions / Declaration of Conformity
Reference 1256-8120 Category Foam fire extinguishers

Technische Daten

Operating system Permanent pressure
Fire class A Rating 27 34
Fire class B Rating 113 183
Capacity 6 ltr. 9 ltr.
Extinguishing agent Foam
Fluorine free Yes
Temperature range °C -25 to +60